NCS37000 interrupter equivalent, ground fault circuit interrupter.
* 6.0
– 12 Volt Operation (120 − 480 V AC mains with the appropriate
series impedance)
* −40 to 85°C
* Very Low Power Consumption: <5 mW @ 5 V.
The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and ground.
The NCS37000 is a fully UL943 compliant signal processor for GFCI applications. The device integrates a flexible power supply (including both shunt and LDO regulators), differential fault, and grounded-neutral detection circuits. Proprietary impedanc.